F.00 N | NTC FAULTS | This means that your Flow NTC (Negative Temperature Coefficient Thermostat) cable is either defective or broken and needs to be replaced |
F.01 | NTC FAULTS (feed temperature sensor) – faulty connection and open circuit. | This means that your Flow NTC (Negative Temperature Coecient Thermostat) cable is either defective or broken and needs to be replaced |
F.10 | NTC FAULTS (feed temperature sensor) – short circuit | — |
F.13 | NTC FAULTS (feed temperature sensor) – short circuit | — |
F.20 | NTC FAULTS (feed temperature sensor) | Your boiler has exceeded the maximum temperature and needs to be allowed to cool down |
F.22 | DRY FIRE, LOW WATER IN SYSTEM/OVERHEAT | This means either there is no water in your system, you have a defective pump or the pump lead is defective |
F.24 | LOW WATER, OR PUMP FAILURE/BLOCKAGE | Your pump could be obstructed, running at low capacity, or there could be air trapped in your appliance. Additionally, the pressure in your system may be too low. |
F.28 | NO IGNITION/IGNITION PROBLEM | This means there is either insucient gas in the system, a defective electrode, ignition lead or electronic ignitor |
F.29 | FLAME EXTINGUISHED. FAN/FLUE PROBLEM/GAS | Your flame, or pilot light has gone out. Check your ue duct or gas supply to see if there is a problem there. |
F.60 | GAS VALVE CONTROL – DEFECTIVE | Your cable loom which connects to your gas valve may have short circuited. Alternatively, you could have a defective gas valve assembly or electronic control system. |
F.61 | GAS VALVE CONTROL – DEFECTIVE | Your cable loom which connects to your gas valve may have short circuited. Alternatively, you could have a defective gas valve assembly or electronic control system. |
F.62 | DEFECTIVE GAS VALVE CLOSURE MECHANISM | Your boiler has exceeded the maximum temperature and needs to be allowed to cool down |
F.63 | EEPROM ERROR | This is an electronic fault within your system. EEPROM stands for Electrically Erasable Programmable Read-Only Memory |
F.64 | ELECTRONIC SYSTEM/SENSOR FAULT | Your ow or backow NTC has suered a short circuit, or an electronic fault |
F.65 | ELECTRONIC SYSTEM TEMPERATURE TOO HIGH | This can happen because of an external heat source or an electrical fault |
F.67 | ELECTRONIC FAULT IN FLAME SYSTEM | — |
- To get your Vaillant Boiler Repaired, call us today on Cardiff 02920 140240
Fault Code
|
Cause of Problem
|
---|---|
F.1 | Lack of gas, a fault with the ignition or flue, or you may need to adjust the gas valve or replace a defective electrode lead |
F.4 | Ignition fault. |
F.5 | The system has suered a fault due to overheating. |
F.6 | Your flow NTC has developed a fault. |
F.17 | Check the polarity of your system |
F.24 | Pump-related faults – the pump could have failed, it may have over run or there could be an issue with the air lock |
- To get your Vaillant Boiler Repaired, call us today on Cardiff 02920 140240

Fault Code
|
Cause of Problem
|
---|---|
F.00, .04, .05, .10, .14, .15 | All of these are NTC faults, and are best resolved by rst changing all NTCs to make diagnosis earlier. |
F.21 | The pilot ame has failed. |
F.22 | There is insucient water in your system |
F.11 | A blockage in the appliance is preventing the system from flowing as it should |
F.12 | A blockage in the appliance is affecting the system’s pressure |
F.13 | The appliance is blocked because of a water deficiency |
- To get your Vaillant Boiler Repaired, call us today on Cardiff 02920 140240

- Call for a Boiler repair today on Cardiff 02920 140240
Call for a Boiler repair today on Cardiff 02920 140240
Checking...
Ouch! There was a server error.
Retry »
Retry »
Sending message...
Request a call back
Please fill in the form and we will call you back
- Mon – Sun 08.00 – 20.00
- Cardiff 02920 140240
- 30 Sandwharf, Cardiff,CF10 7JA
- Gas Safe registration 228349
Warning! It is a criminal offence to work on a gas appliance if you are not qualified, and licensed to do so. ALWAYS consult the manufacturer’s user instructions for guidance. The instructions are for guidance only. If unsure of any procedures, call a boiler specialist, who holds the relevant qualifications, and GAS Safe Registration

Why choose Gas Call to install your boiler?
- Free estimates
- As accredited installers, we provide 5-12 year parts and labour warranties
- Our Engineers are Gas Safe, I.P.H.E. and C.I.T.B. accredited
- We can fast track your Boiler installation
- We will beat quotes from the national gas companies
- Quality workmanship
Gas Safe registration 228349
If you need a quote for a Boiler installation, call us today on Cardiff 02920 140240
Landlord Gas inspections in Cardiff
- Homeowners, Private landlords and Letting agents.
- Online Bookings
- We can fast track urgent inspections.
- Good comunication skills with Tenants.
- Automatic Reminders
- CP12 Landlord Gas Safety certificate issued on site
Gas Safe registration 228349
For a Gas Safety inspection, call us today on Cardiff 02920 140240
Our company policy is being friendly, fast and fair.
Were a team of skilled tradesmen, offering a high standard of service at reasonable rates, all our Cardiff gas engineers keep a simple, fair, and friendly service to our customers.
Mark James ( Gascall company director)